Vetnews | Julie 2026 34 « BACK TO CONTENTS Statistical analysis Data distribution was determined with the Shapiro-Wilk test for normality of data parameters. Continuous data are reported as means ± SD. Comparisons of navigation accuracy, ie, distance from the intended target and procedure duration among participants with different levels of surgical experience, were performed using repeated measures one-way ANOVA. This test was chosen to compare the means across the varying groups with significance set at P < .05 (GraphPad Prism, version 10.6.0). Results The Synaptive Medical CAS system demonstrated compatibility with CT images of the equine cervical spine, enabling effective image registration and real-time navigation (Figure 1). The system successfully processed CT scans to generate accurate 3-D reconstructions, allowing precise registration of fiducial markers on the equine spine. This compatibility facilitated seamless integration of the equine anatomical data into the navigation system, supporting reliable targeting and guidance throughout the procedure. Moreover, fiducial markers placed on the skin and a drilled fiducial array allowed for successful registration in the x, y, and z planes. *Measurement could not be obtained due to user error in the pin not being placed appropriately. FJ = Facet joint. IVD = Intervertebral disc. IVF = Intervertebral foramen. The mean ± SD Euclidean distance for each target with all 3 rounds included was as follows: the intervertebral foramen between C2 and C3 was 10.26 ± 14.53 mm, the articular process joint between C3 and C4 was 12.48 ± 8.12 mm, and the intervertebral disc between C3 and C4 was 11.16 ± 10.72 mm. Interestingly, all pins navigating for the intervertebral foramen between C2 and C3 in cadaver 1 were within the desired area (Figure 2). The overall mean ± SD duration of navigation with the CAS system was 77.81 ± 50.16 seconds per participant. The mean ± SD duration for the Expert participant was 73.44 ± 13.60 seconds, 44.89 ± 27.68 seconds for the Proficient participant, 65.78 ± 8.19 seconds for the Competent participant, and 127.11 ± 13.50 seconds for the Novice participant. Table 1 summarises the mean duration and Euclidean distance for each participant across all 3 cadavers for each target. Table 2 provides detailed results for each individual navigation. Procedure duration differed significantly between the Novice and the remaining participants (Figure 3). However, no statistically significant differences were observed between participants in navigation accuracy. Discussion Computed tomography scans of all cadaveric specimens were successfully acquired and seamlessly integrated into the Synaptive Medical CAS system for registration and navigation. Although the Synaptive Medical CAS system was originally developed for MRIbased neurosurgical applications in human medicine, MRI remains costly and less accessible in veterinary practice. The present study demonstrates that CT imaging, being more widely available, costeffective, and practical in veterinary settings, can be successfully utilised with the Synaptive Medical CAS platform for equine cervical spine navigation. Previous studies12 in human medicine have shown how CT scans for CAS systems provide the benefits of not only increased accuracy but also shorter operation time, fewer postoperative complications, and improved safety. Furthermore, while Synaptive Medical Inc originally indicated the system for cranial applications, our study demonstrates its efficacy in noncranial regions, including the equine cervical spine. These findings suggest that CT-guided navigation could provide a practical and reliable alternative to MRI for translational applications in veterinary spinal surgery. Article A pilot study to assess the feasibility of a computer-assisted surgery system.... <<<33 Participant Average duration of navigations (s) Average Euclidean distance from targets (mm) Expert 73.44 13.13 Proficient 44.89 15.09 Competent 65.78 8.73 Novice 127.11 11.20 Table 1—Mean duration of navigations and Euclidean distance from targets by each participant with varying degrees of surgical experience Participant/ cadaver IVF C2-C3 (mm) FJ C3-C4 (mm) IVD C3-C4 (mm) Expert 1 0.00 11.30 0.00 2 12.24 17.37 12.97 3 Proficient 6.12 14.33 6.48 1 0.00 0.00 32.46 2 40.34 12.12 14.26 3 Competent 11.73 17.81 7.10 1 0.00 11.71 27.63 2 * 17.86 12.62 3 Novice 0.00 0.00 0.00 1 0.00 9.17 0.00 2 35.66 28.68 13.64 3 7.15 6.55 0.00 Table 2—Calculated Euclidean distance from targets by each participant with varying degrees of surgical experience Figure 3—Comparison of duration (A) and accuracy (B) between individuals of different degrees of surgical experience.An ANOVA test was performed for each parameter. There is statistical significance for time but not accuracy between participants with P < .05. Red is the intervertebral foramen C2-C3, blue is the facet joint C3-C4, and green is the intervertebral disc C3-C4
RkJQdWJsaXNoZXIy OTc5MDU=