VN July 2026

Vetnuus | July 2026 35 In this study, the mean ± SD Euclidean distance across all targets was 11.33 ± 11.02 mm, indicating that while the current level of accuracy may not yet meet the requirements for direct clinical application, it supports the feasibility of using CAS for equine cervical spine procedures, specifically cranial cervical spine segments, and establishes a solid foundation for further optimisation. Reported accuracy values for CAS in veterinary orthopaedic applications vary widely. For example, a retrospective equine study8 found mean deviations of 1 to 2 mm. Similarly, a cadaveric study13 placing cortex screws in the proximal phalanx reported a 0.7-mm deviation. Another study14 in cats using CAS for sacroiliac luxation repair reported a 4.2-mm deviation in the first 5 cases, improving to 0.9 mm in subsequent cases. Compared to these studies, the higher mean deviation observed here likely reflects several factors, including the adaptation of a brain-focused software for cervical orthopaedic procedures, manual registration, makeshift instrumentation used for navigation, such as the long spinal needle with poor rigidity, and anatomic complexity in accessing these targets. Historically, spinal imaging and navigation evolved from cranial imaging, where fiducial markers are relatively stable due to the inherent rigidity of the skull.15 In contrast, when adapting CAS systems to the spine, the limited availability of fixed bony landmarks and the potential for fiducial marker displacement can introduce registration errors and reduce accuracy.16 These anatomical and technical challenges likely contributed to the higher deviation observed in the present study. Nevertheless, the Synaptive Medical CAS system demonstrated feasibility for guiding minimally invasive equine spinal procedures, including access to the intervertebral foramina and intervertebral discs. Importantly, the mean accuracy achieved in this study (11.33 ± 11.02 mm) falls within the visualisation range provided by standard minimally invasive dilator systems, which typically allow a working corridor of 10 to 25 mm. Therefore, this level of precision may be sufficient to support procedures requiring limited exposure while maintaining navigational safety. Furthermore, preliminary data from our ongoing studies indicate that this accuracy is adequate to enable navigation-assisted minimally invasive approaches in largeanimal spinal surgery. Studies17 in human medicine have shown that CAS can shorten the learning curve for certain procedures, although greater experience is sometimes required to fully realise its advantages, as reported in total hip arthroplasty.18 In our study, this is reflected by the shorter procedure times of experienced surgeons compared to those of a user without any experience. Only one study has addressed the CAS learning curve in veterinary medicine, as completed by Santistevan et al.19 However, in this study, the comparison between experienced and novice surgeons showed statistical significance when comparing the distance from the target on navigation with a system different from the Synaptive Medical CAS system. Nevertheless, our study demonstrated that the Synaptive Medical CAS system is user-friendly despite experience while highlighting the importance of adequate training to achieve proficiency. This study had several limitations. The small sample size reduced the repeatability and statistical strength of our navigation assessments. The use of previously frozen cadaveric heads and necks likely introduced anatomical distortion due to freeze-thaw cycles, which may have affected accuracy. Image registration also posed challenges, as the system required manual identification of fiducial markers, introducing user-dependent error. In addition, successful registration in all 3 planes (x, y, and z) was difficult, given the lateral cervical anatomy, particularly in achieving consistent alignment in the z-plane. Another limitation involved the instrumentation. Because the Synaptive Medical CAS system is designed for cranial applications, no compatible tools existed for cervical spine navigation, requiring us to fabricate custom instruments for pin placement. Finally, the nonrigid spinal needle used for navigation may have contributed to deviations in trajectory accuracy. Future research on CAS systems could explore clinical applications to cervical spinal procedures, in addition to investigating more caudal cervical spine segments. Moving more caudally involves thicker musculature and penetration to reach the spinal segments. Understanding how this affects the trajectory and instrumentation needed to reach such depth would be important for clinical application. In this study, targeting the articular process joint and intervertebral foramen was a strategic choice based on common cervical spinal procedures performed at these anatomical areas in equine patients. These procedures include ventral interbody fusions for stabilisation or dorsal laminectomies and much newer endoscopic foraminotomies for decompression to treat the most common spinal cord pathology in horses.20 As CAS has been shown to reduce complications in human spine surgery through improved precision and minimally invasive techniques, our goal was to translate these advantages to equine cervical procedures to enhance surgical safety and clinical outcomes. In addition, studies extending to other spinal regions, such as the thoracic and lumbar areas, as well as to other species, should be pursued. Investigating the efficacy of CAS across various species and anatomical regions would provide valuable insights into the system’s adaptability and potential limitations in diverse veterinary contexts. Clinically, CAS could be applied to a range of surgical procedures and techniques beyond spinal navigation, including orthopaedic and neurosurgical interventions, where precision and minimally invasive approaches are crucial. Furthermore, CAS systems hold significant promise for training and education, offering veterinary professionals and students a platform to practice and refine surgical techniques in a controlled, real-time environment.21 Such training could improve procedural accuracy, reduce learning curves, and ultimately enhance patient outcomes. Expanding CAS’s role in veterinary surgery through these avenues would deepen our understanding of its utility and foster its broader adoption in veterinary medicine. In conclusion, this study demonstrates that a CT-based CAS, adapted from a system originally developed for MRI-guided human neurosurgery, is a feasible and promising tool for equine cervical spine procedures. The Synaptive Medical CAS system enabled accurate navigation to anatomically demanding targets such as the intervertebral foramina, articular process joints, and intervertebral discs, supporting its potential use in minimally invasive spinal interventions. Although further refinement and validation in live subjects are warranted, these findings highlight the system’s adaptability to complex spinal anatomy and its translational potential for broader applications in veterinary spinal surgery. Moreover, the study underscores that CAS technology is accessible to surgeons with varying levels of experience, although structured training is essential to ensure proficiency and optimise performance. Taken together, these results establish a foundation for integrating navigation-guided techniques into equine surgery and advancing precision-based approaches in veterinary medicine. Article >>>36

RkJQdWJsaXNoZXIy OTc5MDU=