VN July 2026

Vetnuus | July 2026 33 Article approval from Colorado State University. En bloc cervical specimens were collected postmortem from animals humanely euthanised via IV injection of barbiturate for reasons unrelated to this study. The previous horses’ owners had signed consent forms for postmortem donation of equine cadavers for research and teaching purposes. Osseous and soft tissue structures relevant to surgical navigation, including musculature, ligaments, and joint capsules, were preserved in all cervical specimens. The cadavers were positioned in right lateral recumbency for all procedures. A 3-D–printed custom fiducial array made of polylactic acid filament (Hatchbox; 3.0 mm) was mounted on a 15-cm titanium rod and secured to the dorsal spinous process of C2 (Figure 1). The array contained 6 fiducial markers and was positioned approximately 6 cm above the dorsal surface of the specimen to ensure unobstructed visibility by the navigation camera. Additionally, 4 adhesive fiducial markers (MultiModality Fiducial Markers; Izi Medical) were affixed to the skin along the head and cervical region to facilitate surface registration. Pre- and postprocedural CT imaging was performed to acquire datasets for navigation system registration and accuracy assessment. Scans were obtained using cone beam CT equipment (Siemens Somatom Definition, Siemens Healthineers; or O-arm O2 Imaging System, Medtronic) with acquisition parameters of 120 kV and 35 to 50 mAs. Imaging protocols were optimised to capture high-resolution details of the cervical region (C1-T1), which served as the region of interest for all specimens (Figure 1). The preprocedural CT datasets were imported into the Synaptive Medical CAS system to generate 3-D reconstructions for navigation planning and registration. Successful registration required a minimum of 5 fiducial markers, with at least 1 marker located in each anatomical plane (x, y, and z). Following registration, the total system error was recorded as 3.37, 3.16, and 2.74 mm for cadavers 1, 2, and 3, respectively. Postprocedural scans were used to evaluate the accuracy of instrument placement. Anatomical targets were selected based on clinical relevance, including the intervertebral foramen at C2-C3, the articular process joint at C3-C4, and the intervertebral disc at C3C4. Preoperative planning was performed for all targets, which were accessed individually on the left side while cadavers remained in right lateral recumbency. Trajectories were chosen to minimise distance and avoid obstruction by surrounding anatomy (Figure 2). To evaluate the effect of surgical experience on CAS use, 4 participants with varying expertise were enrolled: a board-certified equine surgeon with 14 years of experience (Expert), another board-certified equine surgeon with 5 years of experience (Proficient), a research veterinarian (Competent), and a second-year veterinary student (Novice). Each participant used radiodense pins of different lengths (5, 10, 15, and 20 mm, respectively) fabricated from 22-gauge needles. Navigation was performed using a 16-gauge X 13-cm spinal needle attached to the Synaptive Medical navigation pointer, with the participant’s assigned pin preloaded at the distal tip for placement at each target site. Procedure duration was recorded for each participant to assess the relationship, if at all, with surgical experience. Following completion of all 12 target placements per cadaver, postprocedural CT scans were obtained using the same imaging protocol as the preprocedural scans. These postoperative images were analysed in Horos software (version 3.6.6), which generated 3-D reconstructions to locate each pin and quantify navigation accuracy. Accuracy was determined by calculating the Euclidean distance between the planned target (point 1) and the distal end of the pin (point 2) using the following formula: Point 1 was estimated as the location within the intended target that minimised the distance to point 2. Pins successfully placed within the target were assigned a Euclidean distance of 0.00 mm. Figure 1—Image of cadaver 1 was acquired with a CT and uploaded into the Synaptive Medical computer-assisted surgery system for registration. Red circles indicate the 6 fiducial doughnuts placed on the skin. The red rectangle indicates the array drilled into the spinous process of C2 with 6 fiducials. Other fiducials were placed on the body, but were not selected due to the maximum limit Figure 2—A—Images from prenavigation and postnavigation. This set of images shows the x, y, and z planes of what is seen in the Synaptive Medical computer-assisted surgery system when setting the target point and trajectory. The yellow “X” denotes the target being the intervertebral foramen C2-C3. B—This set of images shows postoperative CT images after placing the pins based on pre-navigation planning from A. All pins for this navigation were in the desired anatomical area >>>34

RkJQdWJsaXNoZXIy OTc5MDU=