Vetnews | Julie 2026 32 « BACK TO CONTENTS Article Samantha A. Masca, BS1; Jeremiah T. Easley, DVM, DACVS1; Drew W. Koch, DVM, PhD, DACVS1 Juan M. Aragon, BS1; Sam E. Winston, PhD2; Andres F. Bonilla, DVM, PhD1* 1Preclinical Surgical Research Laboratory, Department of Clinical Sciences, Colorado State University, Fort Collins, CO 2Orthopaedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, CO *Corresponding author: Dr Bonilla (andres.bonilla@colostate.edu) A pilot study to assess the feasibility of a computer-assisted surgery system for navigation in the equine cervical spine Computer-assisted surgery (CAS) systems provide real-time visualisation of surgical instruments relative to patient anatomy, facilitating preoperative planning, intraoperative guidance, and postoperative assessment. Its success in human medicine has demonstrated various benefits, including minimally invasive approaches, improved accuracy, enhanced surgical planning, and instrument navigation, ultimately contributing to better clinical outcomes.1–4 In the specific use of CAS for spine surgery, this technology is especially useful for less experienced surgeons in lumbar pedicle screw placement to reduce spinal canal perforation rate and intraoperative time.5,6 The exceptional outcomes associated with CAS have contributed to its growing adoption worldwide. The benefits of CAS have been well documented in human medicine as described above. However, despite its numerous advantages in this field, studies7,8 on the use of CAS in veterinary medicine remain limited. In horses, CAS has been reported to improve accuracy in orthopaedic surgery and neurosurgery. A literary review8 of CAS in equine surgery noted that CAS assisted in the success of equine surgical cases such as a transarticular drilling procedure to promote ankylosis in the distal tarsal joint, removing a fractured articular fragment of the middle phalanx, and curetting an osteolytic lesion on the calcaneal tuberosity. Although these studies show promising results, CAS has yet to become a mainstay in veterinary medicine, in addition to proving its potential in the spinal vertebrae. As this advanced technology becomes more readily accessible to veterinarians, we can expect to see a rapid period of growth and validation. Several CAS navigation systems have been developed for a specific anatomical region, including cranial, spinal, or orthopaedic applications. However, none have been specifically designed or validated for veterinary use. The Synaptive Medical CAS system (Synaptive Medical Inc) was developed for cranial procedures in human medicine9–11 and is optimised for MRI compatibility, as most of its indicated procedures involve neurosurgical access to the brain. Its performance in equine cranial procedures remains unproven, and it has not been tested for noncranial procedures. Evaluating the system’s potential in veterinary surgery could broaden its use for complex neuroanatomical and orthopaedic interventions. Therefore, the objectives of this study were to (1) assess the accuracy and feasibility of the Synaptive Medical CAS system for navigating the equine cervical spine, (2) determine the influence of surgical experience on performance, and (3) identify optimal fiducial marker placement for registration. Methods Three equine cervical spine specimens (C1-T1) were obtained from adult Quarter Horses with no history or clinical evidence of cervical spine disease, which was confirmed by pre-CT images, following Objective To validate the accuracy of the Synaptive Medical computer-assisted surgery (CAS) system for navigation in the equine cervical spine, focusing on anatomical targets that require precise localisation. Methods 3 equine cervical spine cadavers were used (C1-T1) for an experimental study design. A custom fiducial array was mounted into the dorsal spinous process of C2, with additional fiducial markers distributed for landmark registration. Four participants with varying surgical expertise used the Synaptive Medical CAS system to navigate 9 radiodense pins into 3 anatomical targets, including the intervertebral foramen, articular process joint, and intervertebral disc. Pre- and postprocedural CT scans were used to evaluate pin placement accuracy, defined as the Euclidean distance between planned and achieved points. The procedure duration was also recorded. Results The mean navigation error between the planned and reached target points was 11.33 ± 11.02 mm. Surgical experience influenced procedure duration; however, it did not significantly affect accuracy. Additionally, our results suggested that placement of a fiducial array into the dorsal spinous process of C2 allowed for successful registration. Conclusions Use of the Synaptive Medical CAS system for navigation-assisted procedures in the equine cervical spine is feasible and may enhance surgical precision in veterinary applications. Clinical Relevance This study provides insight into the potential integration of CAS into the clinical application of equine cervical spine procedures. This validation supports that CAS can be an option for minimally invasive approaches aimed at reducing clinical complications when accessing the equine cervical spine.
RkJQdWJsaXNoZXIy OTc5MDU=