Vetnuus | June 2026 23 Article Anatomical variability among sea lions, such as differences in age, sex, and body condition, primarily influences overall body dimensions and soft-tissue thickness rather than the relative positioning of vascular landmarks used in blood collection. As such, the presented model captures the essential anatomical features necessary for procedural training across a representative range of adult morphologies. Future work may incorporate morphometric data from multiple individuals to expand this approach into a scalable model library, supporting a wider range of training scenarios and species-specific variations. Beyond its immediate application in veterinary training, the workflow presented here of converting DICOM-standard medical images into scalable, engineered 3D models has broader relevance across multiple disciplines. Similar imaging-based modelling frameworks can support soft robotics design, bioinspired engineering, and the development of biocompatible implants for cardiac, orthopaedic, or neural applications. Recent advances in soft materials and electroactive systems have shown that image-driven fabrication pipelines can bridge biological form and functional engineering design33-35. In this context, the phantom fabrication process described here not only serves as a case study in speciesspecific model development but also as a scalable approach for reproducing complex biological architectures for diverse research and training purposes. Conclusion In this study, a phantom model of a California sea lion pelvis was successfully fabricated for blood collection training. Using the described workflow, DICOM-standard medical images were converted into 3D models through Simpleware ScanIP software, enabling the fabrication of an anatomically accurate engineered model with material properties that closely resemble their biological counterparts. Dynamic mechanical analysis (DMA) was employed to characterise the material stiffness of the Humimic gelatin material at the caudal gluteal blood collection site, emphasising the purpose of material matching in order to simulate the tactile response trainees would expect on the live animal. With a fabrication time of approximately three days, the phantom model demonstrates adaptability for a wide range of anatomical training purposes – provided relevant medical images are available. Future research will focus on enhancing the functionality of the phantom model. Viscosity testing of artificial blood using a viscometer will ensure that the simulated fluid dynamics closely mimic those of real blood, further improving the training experience. In addition, incorporating smart materials for sensing feedback can be seamlessly integrated into the structure of the model, allowing real-time monitoring of trainee performance. The compatibility between these smart materials and medical gels will also be investigated to address challenges in integration. The future direction of this research will be toward integrating compliant electroactive materials into the phantom. Electroactive polymers (EAPs) such as polyvinyl chloride (PVC) gels, hydrogels with additive conductors (carbon nanotubes, polyaniline, etc.) and ionic polymer-metal composites (IPMCs) are novel candidates for phantom electroactive platforms36–40. Inspired by Hunt et al.’s incorporation of coiled polymer actuators into a biomimetic harbour porpoise pectoral flipper, similar methodologies using Simpleware ScanIP data may be applied to further electroactive polymer biomimicry41. These advancements will contribute to developing versatile medical phantom models, broadening their applications in training and soft robotics. By combining innovative material science with computational modelling, this research lays the groundwork for a new generation of customizable and responsive training tools. v References 1. Hespel, A.-M., Wilhite, R. & Hudson, J. Invited review-applications for 3d printers in veterinary medicine. Vet. Radiol. Ultrasound 55, 347–358. https:// doi.org/10.1111/vru.12176 (2014). 2. Dierauf, L. & Gulland, F. M. (eds.) CRC Handbook of Marine Mammal Medicine (CRC Press, Boca Raton, FL, 2001), 2nd edn. Accessed: 2025–04–15. 3. Marine Mammal Anatomy and Pathology Library (MMAPL). Integument and pelage - marine mammal anatomy & pathology library (mmapl) (2023). Accessed: 2024–11–14. 4. Cloonan, A. J. et al. 3D-printed tissue-mimicking phantoms for medical imaging and computational validation applications. 3d Print. Addit. Manuf. 1, 14. https://doi.org/10.1089/3dp.2013.0010 (2014). 5. Wang, K., Ho, C.-C., Zhang, C. & Wang, B. A review on the 3D printing of functional structures for medical phantoms and regenerated tissue and organ applications. Engineering 3, 653–662. https://doi.org/10.1016/J. ENG.2017.05.013 (2017). 6. Wegner, M., Gargioni, E. & Krause, D. Classification of phantoms for medical imaging. Procedia CIRP 119, 1140–1145. h t t p s : / / d o i . o r g / 1 0 . 1 0 1 6 / j . p r o c i r . 2 0 2 3 . 0 3 . 1 5 4 (2023). 7. Laughlin, M. E., Stephens, S. E., Hestekin, J. A. & Jensen, M. O. Development of custom wall-less cardiovascular flow phantoms with tissue-mimicking gel. Cardiovasc. Eng. Technol. 13, 1–13. https://doi.org/10.1007/s13239-02100546-7 (2022). 8. Ho, C. K. et al. Wall-less flow phantoms with tortuous vascular geometries: design principles and a patient-specific model fabrication example. IEEE Transactions on Ultrason Ferroelectr Freq. Control. 64, 25–38. https://doi. org/10.1109/TUFFC.2016.2636129 (2017). 9. Yazdi, S. G., Geoghegan, P. H., Docherty, P. D., Jermy, M. & Khanafer, A. A review of arterial phantom fabrication meth-ods for flow measurement using PIV techniques. Annals Biomed. Eng. 46, 1697–1721. https://doi. org/10.1007/s10439-018-2085-8 (2018). 10. Marine Mammal Commission. Marine mammal commission survey of federally funded marine mammal contaminants research. Tech. Rep., Marine Mammal Commission (2016). Accessed: 2025–02–10. 11. Murrell, J. C. & Robertshaw, D. Utilisation of simulators in veterinary training. ResearchGate (2015). Accessed: 2025–04–15. 12. Fisher, D., Sennain, A., Minaian, N. & Kim, K. J. From bioimaging to artificial anatomy: 3D printing biomimetic marine life structures. In Martín-Palma, R. J., Knez, M. & Lakhtakia, A. (eds.) Bioinspiration, Biomimetics, and Bioreplication XIV, vol. PC12944, PC1294407, https://doi. org/10.1117/12.3001948. International Society for Optics and Photonics (SPIE, 2024). 13. Humimic Medical. Product category - medical gels | humimic medical (2024). 14. Humimic Medical. Gelatin 0 – ballistic gelatin by the pound (2024). 15. Humimic Medical. Gelatin 5 – ballistic gelatin by the pound (2024). 16. Humimic Medical. Gelatin 2 – ballistic gelatin by the pound (2024). 17. Humimic Medical. Gelatin 3 – ballistic gelatin by the pound (2024). 18. Humimic Medical. Easy to use and reuse | humimic medical (2024). 19. Minaian, N., Fisher, D., Sennain, A. & Kim, K. J. Scalable, 3D-Printed phantom of a California sea lion pelvis for veterinary blood extraction training with real-time feedback. In Lakhtakia, A., Knez, M. & Martín-Palma, R. J. (eds.) Biologically Inspired Materials, Processes, and Systems (BIMPS) 2025, vol. >>>24
RkJQdWJsaXNoZXIy OTc5MDU=