VN June 2026

Vetnews | Junie 2026 22 « BACK TO CONTENTS Article Furthermore, the large file sizes associated with high-resolution scans and detailed models present challenges in terms of storage, processing power, and workflow efficiency. Optimising the software pipeline to handle these demands more seamlessly could greatly enhance the usability of this approach. Characterising viscoelastic materials, such as the Humimic gels used in this study, presents unique challenges due to their timedependent stress–strain behaviour. The apparent elastic moduli reported in this study were approximated from stress–strain data obtained during cyclic compressive loading, where the hysteresis loops depicted the energy loss during loading and unloading cycles. While the apparent elastic modulus values align relatively well with previous studies, they are significantly lower than the manufacturer-reported values7,13. This discrepancy likely arises from differences in testing methodologies, including strain rates, testing instruments, and temperature. Despite these variations, the recent calibration of the DMA and the high goodness-of-fit values for the elastic loading region suggest that the reported results accurately represent the mechanical properties under the specific testing conditions. Regarding fabrication, the use of a reusable SLA-printed skin shell provided an efficient and effective method for casting the internal layers of the phantom. Acting both as the external anatomical structure and the negative mould, the shell simplified the alignment of the skeletal model and enabled control over wall thickness and gel distribution. Humimic medical gelatin served as the casting material for the blubber and muscle layers, offering excellent clarity, tunable compliance, and reusability well-suited for repeated training use. Formlabs Draft resin was selected for the skeletal structure due to its balance between mechanical strength and durability. The retrieved Simpleware Scan IP volume fractions compared favourably with marine mammal blubber thickness cited in the literature. Although typical sea lion blubber varies throughout the body, the measured full-scale model blubber thickness of 1.0 ± 0.1 cm was slightly lower than the approximated thickness of 1.6 ± 0.1 cm for the pelvic region of the average reported thickness values of fellow members of the Otariidae “eared seal” family, the Steller sea lion (Eumetopias jubatus)3,31. Therefore, the difference in pelvic region blubber thickness was reconciled due to species differences between the modelled California sea lion and the quantitative reference available in the literature being limited to Steller sea lions as the reference species most anatomically similar. However, this can be expected given that the California sea lion can be significantly smaller than the Steller sea lion32. Some limitations were observed during the fabrication process. The casting process requires precise temperature control and careful handling to prevent defects, such as bubbles or incomplete fills. While Rigid 10 K provided higher stiffness values closer to cortical bone, they were prone to fracturing during fabrication and handling. Draft, by contrast, retained sufficient rigidity both during the fabrication process and in test usage. Despite its successful outcome, the development of this phantom model involved extensive trial-and-error across segmentation, material selection, and fabrication stages, highlighting the iterative and time-intensive nature of translating medical imaging data into functional, anatomically accurate training tools. Future work could explore alternative materials or custom gel formulations to more accurately replicate biological performance. The scalability of the presented fabrication workflow is an important aspect of its utility for training applications. In principle, the process can be implemented at any size, with the primary theoretical limitation being the build volume of the 3D printer and the practical limitations arising from material cost and shipping logistics. A fullscale model, corresponding to an adult California sea lion, which can reach lengths of up to 1.8 m to 2.4 m for females and males, respectively, would provide the most accurate anatomical training experience. However, smaller-scale models may be preferable when portability, material efficiency, or cost are key considerations. The same digital workflow can be readily scaled to either context, offering flexibility to institutions with varying resources or instructional goals. Beyond fabrication feasibility, scalability also impacts material use and associated cost. Table 5 outlines estimated material requirements and total costs for different size scales, illustrating how larger models, while offering greater anatomical fidelity, increase material demand proportionally. Material Per item (pack) Unit price 20% 25% 40% 100% Qty Cost Qty Cost Qty Cost Qty Cost Humimic Medical Gel 0 $42.98 (0.68 kg)14 $0.06321/g 24.2 g $1.53 47.3 g $2.99 193.6 g $12.24 3030 g $191.21 Humimic Medical Gel 5 $42.98 (0.68 kg)15 $0.06321/g 77.4 g $4.89 151.17 g $9.56 619.2 g $39.14 9675 g $611.56 Formlabs Flexible 80A Resin $209 (1 L)30 $0.209/mL 17.32 mL $2.22 45.9 mL $9.59 138.57 mL $28.96 2165.2 mL $452.53 Formlabs Draft Resin $159 (1 L)27 $0.159/mL 29.3 mL $4.66 57.19 mL $9.09 234.2 mL $37.24 3623.69 mL $576.17 Total Cost $10.82 $31.23 $117.58 $1,831.47 Table 5. Material amount and cost at four scales (20, 25, 40 and 100%). Unit prices are based on manufacturer pricing. Humimic gel masses were derived from the volumes listed in Table 2 using density values from the material data sheet14,15

RkJQdWJsaXNoZXIy OTc5MDU=