VN June 2026

Vetnuus | June 2026 19 Article The skeletal structures were 3D printed using a Formlabs Form 3 SLA (stereolithography) printer at up to a resolution of 25 µm, producing models at 20, 25 and 40% scale relative to the original CT scan, with 40% being the maximum stable size given the 3D printer build volume. At each respective scale, a variety of Formlabs proprietary photopolymer resins were used across different prototypes, including Rigid 10 K, Tough 1500, and Draft. Once cured, the skeletal models were gradually dip-coated in heated and evacuated Humimic Gel 0 to simulate tendon, ligament, and muscular tissues closely associated with bone. This layer mimics the stiffer properties of soft tissue near joints and attachment points, which aids in force transfer in contrast to the more compliant muscle tissue further from the bone—often referred to as the “belly” of the muscle20. Furthermore, the dip-coating method was motivated by its novelty as a layer-wise fabrication method, resulting from the assumed noslip condition of the viscous Humimic Gel 0, as well as its thermal sensitivity and insulating properties. Figure 6 shows the final bone print along with the dipping procedure. Considering that the final model is intended for physical handling and training use, the outer shell was fabricated to balance flexibility with structural resilience. This skin shell was also SLA printed using Elastic 50A and Flexible 80A resins to explore differences in compliance under handling without compromising the clarity of internal anatomical structures visible through the surface, as seen in Fig. 6. In addition to serving as an external skin analogue, the shell also functioned as a negative mould for casting the inner blubber and muscle layers using Humimic gelatin. This dual-purpose design simplified assembly and ensured a cohesive structure with proper alignment between internal and external components. For the blubber layer, volume calculations were performed using a control volume analysis in Autodesk Fusion 360. The total internal volume of the entire model was determined from the body properties menu of the outer soft tissue mesh, yielding a value of 42.48 m3. This volume was then normalised to the appropriate scale (20, 25 or 40%) and used to calculate the amount of Humimic Gel 0 and Gel 5 required for casting the blubber and muscle layers, respectively. The relative percentages of these soft tissues were measured using Simpleware’s Volume Fraction tool, determining the volume percentage of the blubber and muscle with respect to the total volume of the model. The volumes of the bone and skin shell were directly extracted from the original DICOM-based segmentations and carried forward into the 3D printing workflow. A summary of the calculated volume fractions and estimated material quantities for each anatomical layer is presented in Table 2. Before casting the 20% scale model, 86.2 mL of Humimic Gel 5 and 27.5 mL of Gel 0 were measured in 100 mL graduated cylinders. The samples were heated to 125 °C for 4 h while simultaneously evacuating in a Napco Model 5831 vacuum oven at approximately − 25 inHg. The assembled mould was suspended in an ice bath. Humic Gel 0 was heated and slowly poured in a spiral pattern along the inner walls of the mould, allowing the highly viscous gel to coat the surface uniformly and settle gently. Once the blubber layer was cast, the skeletal model was inserted and aligned in its anatomically correct position using the naturally occurring alignment features of the mould at the tail and pelvic flippers. The more compliant soft tissue layer, representing muscle, was then cast using heated Humimic Gel 5. This layer was poured until level with the top of the phantom, as shown in Fig. 7a. After curing for 24 h to complete gel cross-linking, heat polishing was selectively applied to the exposed upper surface using a heat gun to smooth imperfections, while avoiding deformation of the skin shell. This process is shown in Fig. 7b. A superior view of the heat-polished phantom can be seen in Fig. 7c, along with a colour overlay indicating the distinct layers of the model (Fig. 7d). Results The following results detail the characterisation and validation of materials selected for use in the quad-layered phantom, specifically those of the gels that had undergone dynamic mechanical analysis (DMA) testing to approximate their elastic properties under cyclic loading conditions. This data then informed the selection of materials to mimic biological soft tissues such as blubber and muscle. Additional components, including the skeletal structure and outer shell, were evaluated based on manufacturer-reported mechanical data and relevant literature. The final phantom outcome was assessed for anatomical fidelity and structural integrity to validate the performance of the proposed image-to-phantom workflow. The apparent elastic moduli of the Humimic gels were approximated using stress–strain data obtained during cyclic compressive loading tests to approximately 25% strain at 1% strain/minute. Mechanical testing involved three continuous loading cycles, and the resulting hysteresis loops were analysed (Fig. 8, left). Linear fits were applied to the elastic loading regions of the stress–strain curves, with 95% confidence bands used to ensure statistical robustness (Fig. 8, right). Due to the viscoelastic nature of the gels, the calculated apparent elastic moduli reflect an approximated stiffness under cyclic loading conditions rather than a static elastic modulus as typically defined. The slopes of these linear fits were recorded for each gel and are presented as effective stiffness values under cyclic loading conditions. These experimental values were then compared to both manufacturer-reported data and the previously published results of Laughlin et al. in Table 3 for validation7,19. The differences between the reported apparent elastic moduli values may stem from variations in testing methodology, including cyclic loading and viscoelastic contributions. The results highlight the significant differences in viscoelastic properties among the gel types, which align with their intended use cases. Stiffer gels, such as Gel 0 and Gel 1, are better suited for applications requiring higher load-bearing capacities, while softer gels like Gel 4 and Gel 5 more closely mimic the behaviour of highly deformable biological tissues. These observations have informed the selection of gels that closely replicate the mechanical characteristics of California sea lion blubber and muscle, where the viscoelastic response plays a key role in energy dissipation. In addition to the DMA testing of the Humimic gels, other materials used in the phantom, such as the skeletal structure and outer shell, were selected based on manufacturer-reported mechanical properties and their alignment with literature values for biological materials. Table 4 presents a comparison of elastic and flexural modulus values for blubber, muscle, and bone against potential 3D printing resins and gels used in this study. >>>20

RkJQdWJsaXNoZXIy OTc5MDU=