Vetnuus | June 2026 17 softer tissues, including fat and muscle, with viscoelastic properties similar to biological counterparts16,17. The gelatin samples were conventionally cast in 10 cm diameter casting dishes, displayed in Fig. 4 (Left). Each Humimic sample container shown in Fig. 4 (Right) was first melted in an oven at 125 °C for four hours until all visual bubbles dissipated, following manufacturer specifications18. The cast gels were then allowed to cool at room temperature for 12 h. Samples were cut in circular cross-sections using a hollow punch of 10 mm diameter with a uniform cross-sectional thickness of approximately 5 mm, measured using a digital micrometre. Each sample container, alongside its respective punched specimens, is shown in Fig. 4. Table 1 details corresponding measurements for each gel sample tested. All mechanical tests were performed using a PerkinElmer Pyris Diamond Dynamic Mechanical Analyser (DMA), with gel specimens placed in the DMA’s isothermal chamber at 20 °C ± 1 °C, ensuring stable temperature conditions across all experiments. The experimental setup can be seen in Fig. 5. Compressive stress–strain hysteresis loading tests were performed on the Humimic gel to 25% strain at 1% strain/minute for three continuous loading cycles. Each gel specimen was compressed by 1 mm at a strain rate of 0.25 mm/min, with a data sampling rate of 1 reading per 5 s (12 samples per minute) over a period of 36 min. A hold of 2 min was applied between cycles to ensure steady-state and zero conditions on the load cell. The linear elastic regions were approximated using a linear fit in OriginLab software with 95% confidence and prediction bands, determining the apparent elastic modulus of each gel and the corresponding goodness-of-fit statistics. Phantom fabrication Fabricating a biologically realistic training phantom requires deliberate material selection to replicate the distinct mechanical properties of the materials being modelled. Four distinct components were individually created to capture a quad-layered morphology: the skeletal structure, a compliant skin shell representing the dermis and epidermis, an adipose-rich blubber layer, and an internal muscular layer. >>>18 Article Figure 3. Workflow for developing multi-material 3D-printed anatomical phantoms from CT imaging data. A DICOM stack of 2D cross-sectional CT images was imported into Synopsys Simpleware ScanIP for image processing, segmentation, and mask refinement. Bone and soft tissue components were segmented separately and exported as STL files following decimation. The bone STL model was imported directly into Autodesk Fusion 360 for print preparation, while the soft tissue shell underwent mesh conversion and surface processing prior to mould generation Figure 4. (Left) Aluminium casting dish (10 cm diameter) with cured gel. Samples were extracted at the circular visual indicator using a 10 mm diameter hollow punch; (Right) Humimic gel samples of formulations #0—#5 tested within the PerkinElmer Pyris Diamond Dynamic Mechanical Analyser (DMA)
RkJQdWJsaXNoZXIy OTc5MDU=