VN April 2024

Vetnews | April 2024 12 « BACK TO CONTENTS Discussion Respiratory diseases (especially pneumonia) are very common disorders in pet rats (22, 23). The suspected diagnosis is mostly based on the clinical signs, thoracic auscultation, and thoracic radiography. However, the auscultation is insensitive to determining the severity of the disease, and radiographs are commonly unremarkable (24). A computed tomography examination seems to be promising in the diagnosis of intrathoracic disease (25) however, this examination is still not available in many veterinary practices. In recent years, pleura and lung ultrasounds have become important tools in human and veterinary medicine (3, 25). It has been shown to be a suitable imaging method for the diagnosis of pulmonary oedema (26–28), pneumonia (29), and pneumothorax (30, 31). Many studies have shown thoracic sonography to be the preferred method for identifying lung and pleural pathological findings when compared to computed tomography, especially due to the lack of radiation exposure and similar examination results. Furthermore, the advantage of thoracic ultrasound is the possibility of performing it ‘bedside’, in contrast to computed tomography (CT) or thoracic X-rays (TXR) (32–36). In RATTUS, the major advantage is the possibility of performing this examination in conscious animals and in normal sternal recumbency. The thoracic ultrasound was mainly described in rodent experimental studies (2, 20, 37, 38). In mice, lung ultrasound has been successfully used to assess pulmonary congestion in a preclinical model of heart failure (39). In companion rats, only a few studies and clinical case reports of thoracic diseases have been published; however, none of them used thoracic ultrasonography as a diagnostic method (21, 40–44). On the contrary, thoracic ultrasound in companion animals is a standard and well-described diagnostic tool for the diagnosis of cardiogenic oedema (45, 46), pneumothorax (3, 47), pleural effusion (3, 48, 49), or pneumonia (50, 51). One of the limitations of this examination is the presence of pathological conditions outside the lung periphery, which may be missed due to the aerated lung causing a ‘physiological’ reverberation artefact (20, 52). Another limitation may be rib shadowing, where smaller pathologies may remain hidden (this issue is partially decreased using the transversal view of intercostal spaces and the fact that most clinically manifested disorders occur in larger areas) (52). Due to these limitations, other imaging techniques such as CT and TXR could be useful to provide a complete thoracic cavity overview. Pleura and lung ultrasound are considered to be a safe, cost-effective, and easily implemented imaging modality that can aid in the assessment of many thoracic pathological findings. It has been shown to improve procedural efficiency whilst decreasing complications, increasing success, and reducing financial strain (53). In the medical treatment of pet rats, the main advantage of RATTUS is the possibility of evaluating the thoracic wall without anaesthesia (in contrast to TXR or CT) (43). Due to the size of the thoracic cavity and the use of a linear probe, the examination is relatively quick and easily conducted. Another advantage of this technique is the repeatability of the examination, which enables the evaluation of the progression of the disease and/ or the efficacy of therapy. However, we have not assessed the repeatability of the RATTUS protocol. The RATTUS protocol and normal ultrasonographic findings reported in the present study may be useful for a routine thoracic examination in pet rats. Further studies in acute and chronic cases of respiratory distress are needed. Publisher’s note All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher. v Supplementary material The Supplementary material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fvets.2024.1286614/ full#supplementary-material SUPPLEMENTARY VIDEO 1: Physiological sonogram https://1drv.ms/v/s!AglSmr1cGU9agRcvHFeUBQ7BLkVW SUPPLEMENTARY VIDEO 2: The curtain sign https://1drv.ms/v/s!AglSmr1cGU9agRiGIcTXyRE7A7Lt SUPPLEMENTARY VIDEO 3: The ski jump sign https://1drv.ms/v/s!AglSmr1cGU9agRlmPhD2KTf8780n SUPPLEMENTARY VIDEO 4: The lung pulse https://1drv.ms/v/s!AglSmr1cGU9agRomosFYJAwxvrhw SUPPLEMENTARY VIDEO 5: The substernal access https://1drv.ms/v/s!AglSmr1cGU9agRtjcWcRscUZPJkG Leading Article (The Rat Thoracic Ultrasound protocol....) Figure 10 Single B-line (arrow) on linear probe proven by changing depth (A−E—A: depth 2 cm, E: depth 9 cm). The micro-convex probe is usually recommended for vertical artefact assessment; however, by increasing the depth of the image, there is the ability to con firm that B-lines are ‘true’ B-lines and did not terminate before reaching the far field of the ultrasound image.

RkJQdWJsaXNoZXIy OTc5MDU=