Vetnuus | September 2021 32 Regulars I Ophthalmology Column Bothmedical and veterinary ophthalmologists frequently need toperform an electroretinograph [ERG]. Many veterinarians have been exposed to this term when reading patient reports from the ophthalmologist but may not fully understand the rationale behind this very important tool that we have. Electrodiagnostic testing provides a unique, non-invasive opportunity to probe the visual system from the retina to the visual cortex in most animal species. This technology measures the electrical potentials generated in various parts of the visual system. It is important to realize it is not a measure of grading of vision. The ERG is a complex response from different cells within the retina which may be useful in diagnosing outer retinal disease. The ERG allows us to assess the function of the retina which is visible through an ophthalmoscope and is thus considered to be an electrical mass response of the retina to light stimulation, which reflects the function and integrity of the photoreceptors and other retinal cell layers. The first ERG was performed in 1865 but only really applied clinically in 1941 and then later in 1967, Ragnar Ganit pioneered most of the research on ERGs to what we know today and for this, he received a Nobel Prize. The equipment involves: • the commercially available computer software that acquires the data from the electrodes following a flash stimulus. These signals generated from the retina are very small in amplitude and then need to be magnified approximately 10 4 times to be properly visualized. Hence the amplitudes are presented in microvolts. Signal averaging will also reduce the impact of background noise. • A photo stimulator – this can be a strobe-type light or a light- emitting diode [LED]. The light source should try and provide uniform illumination to the retina. • Electrodes – the electrical changes produced by light stimulation of the retina are usually recorded using an active electrode touching the cornea. This is a gold leaf JET contact lens electrode. A topical anaesthetic and a contact gel are used. A reference needle electrode is placed subcutaneously in the skin just lateral to the lateral canthus and then a ground needle electrode is placed subcutaneously on top of the head between the ears. • The patient is dark-adapted for 15 minutes in a room with a red light when rod measurements are to be performed. • For routine ERGs the patient is conscious but sedation or general anaesthesia may be required to maintain proper fixation when more comprehensive ERG testing is required for research purposes. The ERG is usually reported by providing values for the implicit times and amplitudes for the “a” and ‘b”waves. [see figure below]. a-wave : a rapid cornea-negative potential deflection: This reflects the negative change in the intracellular charge of photoreceptors [hyperpolarization so more negative] caused by the light-evoked closure of the sodium channels in the cell membrane. This is from rods when scotopic [dark] conditions apply [dark room] and cones with increasing stimulus strength or from cones when photopic conditions apply and rods are suppressed. b-wave :Thus is a corneal-positive deflectionprimarily fromON rodbipolar cells, with a later negative component from OFF bipolar cells. Other glia cells like Muller cells, amacrine -, and ganglion cells also affect amplitude and shape. This wave is measured from the trough of the a-wave to the following positive peak. The Oscillating potentials [OPs] are a series of wavelets superimposed mainly on the ascending limb of the b-wave. This waveform is thought to be generated by a radial current flow driven by amacrine cells. Retinal ischemia may cause the reduction of OPs. Amplitudes will decrease and implicit times increase when intraocular pressure during glaucoma occurs. OPs will be abnormal in disorders primarily affecting the outer retina because input from the outer retinal cells to the amacrine and interplexiform layer will be reduced. Such an example will be dogs with rod-cone dystrophy. The Electroretinograph [ERG] Dr Antony Goodhead, Specialist Veterinary Ophthalmologist, Johannesburg and Cape Animal Eye Hospitals, (www.animaleyehospital.co.za )
Made with FlippingBook
RkJQdWJsaXNoZXIy OTc5MDU=