VN March 2021
Vetnuus | Maart 2021 30 Recently, a number of colleagues have decided to invest in a more modern tonometer for measuring intraocular pressure. This month’s ophthalmology column is going to discuss this instrument and how to use it. The TonoVet is a valuable tool as it is portable, very user-friendly, lightweight and has a lightweight probe that makes only a brief corneal contact and requires no topical anaesthetic. This probe or pin has a head that is small (1mm diameter), round tipped and light (11mg). This rebound or “induction-impact” instrument calculates intra-ocular pressure (IOP) based on the deceleration of the relatively slow moving pin (0.1- 0.2m/s) as it comes into contact with the cornea. The pin’s motion is monitored by a solenoid in the tonometer which also serves to propel the magnetic pin – i.e., it is electromagnetically expelled from the chamber and comes into contact with the cornea. The movement energy of the probe is very small (less than 0.25uJ) and most of that is rebounded (not absorbed by the eye) so there is no damage to the eye. The rate of deceleration of the probe once in contact with the cornea determines the IOP. The higher the IOP, the more rapid deceleration and the shorter contact time the probe has with the cornea. The internal manufacturers calibration can be adjusted for dogs, cats and horses. The instrument takes 6 consecutive readings and automatically discards the highest and lowest and presents the average in a small LCD screen. Positioning the patient is important. Generally, the IOP is taken in cats and dogs in sternal recumbency, with the head held gently. The instrument is brought horizontally to between 3 and 7mm from the cornea and the trigger depressed to cause the probe to touch the cornea and take the readings. It has been shown that in cats the IOP is significantly increased when there is dorso-ventral extension of the eyelids as well as lateral extension of the eyelid. This is very important and often there is a tendency to want to grasp the head firmly in slightly uncooperative cats with one’s hands in order to take a reading. Researchers also found that constricting the jugular lowered IOP but it was not statistically significant (unlike in dogs). The TonoVet®, is especially useful for obtaining intraocular pressures from scarred, oedematous, irregular, or severely damaged corneas. An IOP can still be recorded safely in a cornea with a Descemetocoele unlike other instrumentation such as the Shiotz tonometer. It can also measure intraocular pressure through a bandage contact lens and with the patient in any position. Its portability and ease of use are important advantages. There are some general concepts regarding factors that affect IOP : • The probe must be horizontal (parallel to the floor) • Do not apply excessive pressure on the head or neck. • It has long been recognised that pressure on the jugular veins from excessive restraint or a tight-fitting collar may falsely elevate the IOP, particularly in brachycephalic dogs. One of the very good reasons to use chest harnesses especially after cataract surgery. Two theories have been hypothesised regarding the raised IOP with jugular constriction. The first is that neck pressure causes resistance to outflow of aqueous humour because of increased pressure in the episcleral vasculature from jugular pressure and resultant venous stasis and secondly that jugular pressure leads to increased choroidal blood volume caused by venous stasis. • Head position –generally the IOP is taken with the patient [cats and dogs] in sternal recumbency on a table. Three different body positions in dogs have been compared (sternal recumbency, dorsal recumbency, and the sitting position) and found to affect IOP. During the 5-minute examination, IOP decreased significantly in dogs that were dorsally recumbent or sitting but did not change significantly in dogs that were sternally recumbent. • In the case of horses, standing with head held up is the normal position. In large species such as the horse, and when an eye is painful, adjunctive methods may be required for attaining a reliable tonometry. These include sedation, general anaesthesia, and regional nerve blocks. For reliable tonometry in the clinical setting, the use of an auriculopalpebral nerve block is recommended in the horse. Head position was also found to have a significant effect on IOP in normal horses. Two different head positions, above and below heart level, were assessed following sedation (intravenous detomidine), auriculopalpebral nerve block, and topical corneal anaesthesia. The IOP was increased in 87% of eyes when the head was below heart level, and there was a significant difference from the mean IOP when the head was above the rebound tonometer probe. • Topical tropicamide 1% has been shown to cause a substantial increase in IOP (up to 6–7 mmHg) in both normal and glaucomatous cats. Topical tropicamide 1% has less effect on IOP in the dog, although clinically relevant increases in individual animals. • In the dog, ketamine sedation alone causes a significant and clinically important increase in IOP The use of the rebound, Tonovet® tonometer Dr Antony Goodhead, Specialist Veterinary Ophthalmologist, Johannesburg and Cape Animal Eye Hospitals, (www.animaleyehospital.co.za ) Regulars I Ophthalmology Column
Made with FlippingBook
RkJQdWJsaXNoZXIy OTc5MDU=